Especificaciones:
-
Remote ON/OFF Control : The power supply shall accept a logic open collector level which will disable/enable all out put voltage (excluding +5V standby)
-
Output voltage hold-up time :
-
Operation at no load : The power supply will be capable of being operated with no load on any or all outputs without damage.
-
Over voltage protection :
-
+5V : 6.5V(max.)
-
+3.3V : 4.6V(max.)
-
+12V1 : 15.5V(max.)
-
+12V2 : 15.5V(max.)
-
Over current protection : There shall be protection from an output over-current event. The power supply may shutdown from such an event and require power-on restart. Testing consists of application of the listed over-current value with maximum load on all other outputs. Over-current test values: (maximum load)
-
+3.3V : 80A(max.)
-
+5V : 68A(max.)
-
+12V1 : 45A(max.)
-
+12V2 : 45A(max.)
-
Short current protection : A short circuit at any output shall cause no damage to the power supply nor blow the primary fuse. The power supply may shut down in the event of a short circuit and require power-on restart. A short circuit consists of application of a test resistance of less then 0.05 ohms at each output with maximum load on all outputs.
-
Output risetime : The cold-start enable output voltage risetime of all outputs shall be measured with maximum load on all outputs. Riseti me (10-90%):
-
+3.3V 20mS (max.)
-
+5V 20mS (max.)
-
+12V 20mS (max.)
-
+12V 20mS (max.)
-
+5Vsv 20mS (max.)
-
Output overshoot : No output voltage shall overshoot or generate spikes at turn-on or turn-off, during momentary power loss, output short, or realistic input voltage or output load changes. Overshoot is defined as any output that exceeds the voltage tolerance plus or minus an additional 5%.
-
Efficiency : Overall efficiency must be 70% min. measured at normal AC mains voltage and frequency with maximum loads on all outputs.
-
Power good signal : 115/230V (full load): 100-500mS
-
Temperature range :
-
operating 0 o C~50 o C
-
storage -20 o C~+65 o C
-
Relative Humidity : 90%
-
Safety requirements : TUV EN60950, NEMKO + CB REPORT, IEC 60950, UL 60950
-
Dielectric strenght : Primary to frame ground: 1800 Vac for 1 sec. Primary to secondary: 1800 Vac for 1 sec.
-
Insulation resistance : Primary to secondary: 20 Meg. ohms min. Primary to frame ground: 20 Meg. ohms min.
-
Ground leakage current : The power supply ground leakage current shall be less than 3.5mA
|
3.3V & +5V total output not exceed 200Watt |