Output overshoot: No output voltage shall overshoot or generate spikes at turn-on or turn-off, during momentary power loss, output short, or realistic input voltage or output load changes. Overshoot is defined as any output that exceeds the voltage tolerance plus or minus an additional 5%.
Efficiency: Overall efficiency must be 70% min. measured at normal AC mains voltage and frequency with maximum loads on all outputs.
Power good signal: 115/230V (full load): 100-500mS
Temperature range:operating 0oC~50oCstorage -20oC~+65oC
Relative Humidity: 90%
Safety requirements: CE, TUV EN60950, NEMKO + CB REPORT, UL 60950, CSA
Dielectric strength:
Primary to frame ground: 1800 Vac for 1 sec.
Primary to secondary: 1800 Vac for 1 sec.
Insulation resistance: Primary to secondary: 20 Meg. ohms min. Primary to frame ground: 20 Meg. ohms min. |